KVCalc · Transformer and electrical tools
Free Transformer & Electrical Calculators
Sizing, nameplate and instrument tools that show the calculation and the source behind every result.
Available calculators
Installing a transformer? Work in this order.
- Pick the kVA: load in kW, kVA or amps to the next standard size.
- Set the primary fuse or breaker: NEC 450.3, with a pass/fail check.
- Size the secondary conductors: ambient, conductor count and terminal limits.
Step 1 · kVA · Sizing
Transformer Sizing Calculator
Load in kW, kVA or amps to the next standard transformer size, with full-load current on both sides.
Open calculatorStep 2 · NEC 450.3 · Protection
Transformer Fuse & Breaker Size Calculator
Primary and secondary overcurrent protection up to 34.5 kV, with visible arithmetic and a pass/fail check.
Open calculatorStep 3 · NEC 310.16 · Conductors
Secondary Conductor Sizing Calculator
Choose conductor size with ambient correction, conductor-count adjustment and terminal limits.
Open calculatorNameplate · Date code
Transformer Serial Number & Date Code Decoder
Read the manufacture date from a serial number. Each rule is labeled published or reported, with its source.
Open decoderCurrent transformers · IEEE C57.13
CT Burden Calculator
Check metering burden against the CT rating, or a C class relaying CT for saturation.
Open calculatorShort circuit · Point-to-point
Available Fault Current Calculator
Fault current from transformer kVA, voltage and nameplate %Z, then through each cable run.
Open calculatorAutotransformer · NEC 450.4
Buck-Boost Transformer Calculator
Supply voltage, load voltage and amps to the output voltage, unit kVA, max load current and the fuse or breaker limit.
Open calculatorConductors · Voltage drop
Voltage Drop Calculator
Volts lost on a run, the smallest wire for your target and the longest run a size allows.
Open calculatorConductors · Conduit fill
Conduit Fill Calculator
Fill percentage, smallest conduit and max wire count for EMT, RMC and PVC Schedule 40.
Open calculatorPower conversion · kVA · kW · Amps
kVA / kW / Amps Calculator
Convert kVA, kW and amps for DC, single-phase and three-phase systems.
Open calculatorEvery result names its source · Free, no signup · More calculators are planned.
Questions people actually ask
What is KVCalc?
KVCalc is a set of free transformer and electrical calculators. Each result names the code, standard or document it came from, such as the NEC for transformer protection and conductor sizing, IEEE C57.13 for current transformer burden, and manufacturer documents for serial number formats.
Which edition of the NEC do the calculators follow?
The 2023 National Electrical Code (NFPA 70). Jurisdictions adopt different editions on different schedules, so always check which edition your local authority (AHJ) enforces before committing to a size.
What size fuse do I need for my transformer?
It depends on the kVA rating, voltage, and protection method. Enter those values in the transformer protection calculator and you get the code-cited amp rating, the arithmetic behind it, and whether the selection passes. As a rough guide, a 75 kVA 480 V three-phase transformer lands on a 125 A fuse.
Is KVCalc free? Do I need an account?
Yes, free, and no account or signup. Open the calculator, enter your values, and share the result link with anyone — the link carries the full calculation.
Can I use these results for an inspection or permit?
Use them as a checked starting point, not the final word. Each result names the code, standard or document behind it so an engineer or inspector can verify the path in seconds. Transformer protection affects life safety, so confirm against the source and the edition your jurisdiction adopted.
How do I size transformer secondary conductors?
Enter the transformer rating, secondary voltage and installation conditions in the secondary conductor sizing calculator. It applies continuous-load, ambient, conductor-count and terminal limits, then shows which constraint governs the selected size.
What is the difference between NEC 450.3(A) and 450.3(B)?
The test is a single number: the primary voltage. Table 450.3(B) applies at 1000 V or less; Table 450.3(A) applies over 1000 V and additionally depends on transformer impedance and supervised status. The calculator switches tables automatically.