Calculators that cite their own authority
Free transformer and electrical calculators for learning and reference. Each page names the code, standard or document its numbers come from.
Who runs this site
I'm Allen Tan, a transformer B2B export specialist based in Guangdong, China. My day job is real export orders, spec sheets, and technical questions from buyers in the US, Europe, and Southeast Asia — ring core, EI, dry-type, and oil-immersed units, not textbook examples.
I'm not a licensed engineer, and this site won't pretend otherwise. What I do is narrower — and checkable: each tool on KVCalc names the code article, standard or document behind its numbers, so anyone can verify the path in seconds.
How every number is verified
- Code first. The NEC tools implement coefficients and limits from the NEC text itself. They are built against the 2023 edition (NFPA 70). Where a page says it compared the 2026 edition, it names what was compared: for example, the transformer fuse tool found that 450.3 became 450.5 in 2026 with the same percentages. A comparison is not a claim of full 2026 support. Editions change numbering and coefficients between revisions, so confirm which edition your jurisdiction enforces.
- Other tools cite other sources. The CT tool uses IEEE C57.13 and the NEC wire resistance table. The serial number decoder uses manufacturer documents where the maker publishes a format. Where only a third-party record exists, the result is labeledreported, with its source, and is not presented as confirmed by the maker.
- Cross-checked, with sources graded. Manufacturer documentation and official code or standard text rank highest. Secondary sources such as third-party calculators are used only to cross-check, and where they disagree with a higher-grade source, the higher-grade source wins. When no published rule is found, the tool says so.
- Conservative where ambiguous. Where the Code sets a maximum, the tool rounds down and says so. Where it permits rounding up, it cites the exact note that allows it.
How the pages are made
AI tools help draft the code and the page text. Every value that comes from a code, standard or manufacturer document is entered from that source, and each calculator runs against an automated test suite before it is published. The test suite checks the arithmetic and the rules; it does not replace reading the source.
What these tools are not
Nothing here is engineering advice or a substitute for the code text. Transformer protection decisions affect life safety. Verify every result against the source document named on the page and with the engineer or inspector responsible for the installation (your AHJ).
Corrections
If a result looks wrong, the source document wins over this tool. Send the inputs and the output to [email protected] and it will be checked against the source.